Seed meter settings, Seed meter settings -6, Kpm iii monitor operation – Kinze 3110 Mounted Planter Rev. 7/14 User Manual

Page 80

Advertising
background image

M0244-01

Model 3110

5-6

9/12

TM

KPM III Monitor Operation

KPM III Monitor Operation

SEED METER SETTINGS

STEP 1

Scroll to ‘‘2. Seed Meter Settings” by turning rotary

encoder knob or using arrow keys. Press knob or

Enter key to display highlighted item.

STEP 2

Select meter type by highlighting “Meter Type” and

pressing knob or Enter key, then highlight “Mechanical”

or “Vacuum” and press knob or enter key.

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

Logdata

10.Calibrate Speed Sensor

Status

Plant

About

Setup Mode

Configuration:

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

Logdata

Seed Meter Settings

Cancel

OK

Meter Type

Crop Type

Seeds per rev

Interplant

Vacuum

Enabled

Meter Sprocket

teeth

Corn/Popcorn

39

28

Seed Size

10

nominal 10, min 0, max 31

1 2 3

C

4 5 6
7 8 9

.

0

-

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

10.Calibrate Speed Sensor

Logdata

Seed Meter Settings

Cancel

OK

Meter Type

Crop Type

Seeds per rev

Interplant

Mechanical

Enabled

Corn

12

Meter Sprocket

19 teeth

NOTE: when Mechanical Meter Type is selected Meter

Sprocket automatically sets.

NOTE: when Vacuum “Meter Type” is selected “Meter

Sprocket” automatically defaults to 28 teeth. To change

Meter Sprocket select “Meter Sprocket” by turning knob

or using arrow keys. Press knob or enter key, a drop down

number pad displays. Turn knob or use arrow keys to

highlight first digit of desired number and press knob. when

correct number is obtain press knob or enter key.

Status

Plant

About

Setup Mode

Configuration:

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

Logdata

Seed Meter Settings

Cancel

OK

Meter Type

Crop Type

Seeds per rev

Mechanical

Interplant

Enabled

Corn

12

Meter Sprocket

19 teeth

Soybeans

Vacuum
Mechanical

Vacuum

Seed Size

10

nominal 10, min 0, max 31

STEP 3

Turn knob or use arrow keys to highlight “Crop Type”.

Press knob or Enter key to display crop drop down

menu.

STEP 4

Turn knob or use arrows keys to highlight a crop for

planting then press knob or Enter key. Once crop

type is entered, “Seeds per rev” is automatically set .

A sensitivity threshold (Seed Size) ensures dust and other debris are

filtered out and only actual seeds are counted. Sensitivity threshold is

set to a default for a selected crop which is adequate for most conditions.

Sensitivity can be set between 0 and 31, 0 being most sensitive

(counts smallest particles) and 31 least sensitive (counts large

particles). Adjust threshold one value at a time until desired result

is achieved. Once value is changed it becomes default for that crop.

NOTE: Adjusting threshold too high can cause monitor to

miss seeds and provide inaccurate information. Always

do a ground check to ensure monitor is reading accurately.

STEP 5

Select “Seed Size” and press ENTER key. A

drop down number pad displays.

STEP 6

Turn knob or use arrow keys to highlight first digit

of desired number. Press knob. When correct

number is obtained, press knob or Enter key.

STEP 7

Turn knob or use arrow keys to highlight “Crop Type”.

Press knob or Enter key to display the crop drop

down menu.

STEP 8

Turn knob or use arrows keys to highlight a crop

for planting then press knob or Enter key. Once

crop type is entered, the “Seeds per rev” is set

automatically.

Status

Plant

About

Setup Mode

Configuration:

Front / Rear

1. General Settings

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

Logdata

Seed Meter Settings

Cancel

OK

Meter Type

Crop Type

Seeds per rev

Interplant

Vacuum

Enabled

Meter Sprocket

teeth

28

39

Cancel

Corn/Popcorn

Corn/Popcorn

Low Rate Corn/Popcorn

Soybeans

High Rate Soybeans

Cotton
Hill Drop Cotton
Milo/Grain Sorghum
Large Dry Edible Beans
Other Large Seed
Other Small Seed

Seed Size

Seed Meter Settings

Cancel

OK

Meter Type

Interplant

Mechanical

Enabled

Soybeans

Seeds per rev

60

Meter Sproc

19

teeth

ket

Crop Type

Seed Size

nominal 10, min 0, max 31

39

1 2 3

C

4 5 6
7 8 9

.

0

-

10

Advertising