Kpm iii monitor operation – Kinze 3110 Mounted Planter Rev. 7/14 User Manual
Page 92
M0244-01
Model 3110
5-18
9/12
TM
KPM III Monitor Operation
Start
Help
Done
TEST MODE
Test mode report:
Rear Row 1 0.00% 0 out of 0
Rear Row 2 0.00% 0 out of 0
Rear Row 3 0.00% 0 out of 0
Rear Row 4 0.00% 0 out of 0
Rear Row 5 0.00% 0 out of 0
Rear Row 6 0.00% 0 out of 0
Rear Row 7 0.00% 0 out of 0
Rear Row 8 0.00% 0 out of 0
Front Row 1 0.00% 0 out of 0
Front Row 2 0.00% 0 out of 0
Front Row 3 0.00% 0 out of 0
Front Row 4 0.00% 0 out of 0
***
***
STEP 5
TEST MODE screen displays test run data (seed
count) for each row.
STEP 6
Begin test with tractor stopped. For EdgeVac
planters, ensure vacuum is on and seed discs are
full.
STEP 7
Press F1 key next to Start and plant a test strip.
STEP 8
Stop tractor and press “End”. KPM III displays seed
counts by row and percentage.
NOTE: Above instructions display on screen when F2 key
next to “Help” is pressed.
STEP 9
Press F6 key next to Done. Display returns to Mode
Selection screen.
Setup Mode
Install
Remove
Ignore
Revive
Done
Rear Row 7 OK
Rear Row 6 OK
Rear Row 8 OK
Front Row 1
OK
Front Row 2
OK
Front Row 3
OK
Front Row 4
OK
Front Row 5
OK
Front Row 6
OK
Front Row 7
OK
Rear Row 11 0.00% 0 out of 0
Rear Row 12 0.00% 0 out of 0
View
Sensor Setup
[Auto Detect]
Test Mode Operation
1 Begin with the tractor stopped. For Edge-Vac
planter, ensure that the vacuum is on and that
the seed discs are full.
2 Press Start and plant a test strip.
3 Stop the tractor and press End.
The KPM III will display seed counts.
OK
Status
Normal
Average
Section
Freeze
8.75
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
ACF
R2
Pop
Scan
30556
ROw POPULATION
Press F1 key next to “RowPop” to display row population.
Average planter population is shown in lower L.H. corner of
display.
Status
Normal
Average
Section
Freeze
8.75
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
ACF
R2
Pop
Scan
30722
• Press F3 key next to Scan. Monitor scans through each row in
ascending order displaying average seed population for each
row. After all rows have been scanned, average population
displays and scan function continues with first rear row.
• Press F3 key next to Freeze to stop scanning. Left display item
will be frozen on a particular row. “Frzn” appears in lower L.H.
corner to indicate display is frozen. To resume scan press F3 key
next to Scan.
ExAMPLE: when average individual row population is
shown, R3 indicates rear row 3, F2 indicates front row 2, etc.
• When “Scan” or “Frzn” is displayed in L.H. corner, Section
and arrow keys function as follows:
• Section, Right arrow key, or Left arrow key advances to the
first rear row.
• Up arrow key moves forward to the next row of the planter,
wrapping around to the first row when moving past the last
row.
• Down arrow key moves backward to the previous row of the
planter, wrapping around to the last row of the planter when
moving past the first row.
• Press F4 key next to Average to display average population
in bottom L.H. corner.
• Press F2 key next to Normal to display normal screen for
Planter Configuration screen.
NOTE: If rows are being scanned and F4 key next to
Average is pressed, scan function stops.
Status
Normal
Average
Section
Freeze
Avg
Pop
Scan
30607
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
MPH
5.0