26 signal conversion (conv), Signal conversion (conv), Function library – Lenze EVS9332xK User Manual

Page 136: Function blocks

Advertising
background image

Function library

Function blocks

3.2.26

Signal conversion (CONV)

3−108

l

EDSVS9332K−EXT EN 4.0

3.2.26

Signal conversion (CONV)

Purpose

These function blocks can be used to standardize signals or signal types or to convert signal types
into different signal types.The conversion is very precise by providing the conversion factor as
numerator and denominator.

CONV1

C 0 9 4 2

C 0 9 4 3

C O N V 1 - I N

C O N V 1 - O U T

C O N V 1

C 0 9 4 0
C 0 9 4 1

C O N V 1 - D F O U T

fb_conv1

Fig. 3−78

Function block CONV1

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV1−IN

a

C0943

dec [%]

C0942

1

1000

CONV1−OUT

a

Limited to ±199.99 %

CONV1−DFOUT

phd

Limited to ±29999 rpm

This function block is used to multiply or divide analog signals.

CONV1−OUT

+ CONV1−IN @

100 %

15000 rpm

@ C0940

C0941

or

CONV1−DFOUT

+ CONV1−IN @ C0940

C0941

[rpm]

Example:

An analog signal is to be multiplied by 1.12.
For this, enter C0940 = 112 and C0941 = 100.

Advertising
This manual is related to the following products: