Characteristic function (CURVEC)

3−135

l

EDSVS9332K−EXT EN 4.0

Max. permissible input value exceeded

A fault is indicated for input values X>Xmax:

l

CURVEC1−X > X

max

= HIGH

Furthermore, the output will show the y value which would result from the profile function for X=Xmax.

)

Note!

X

max

is already determined when the profile is generated (GDC).

3.2.38.1

Selection of profiles stored in the controller

Procedure

1. Inhibit the controller or set CURVEC1−X−RESET = HIGH.

)

Note!

If you have neither inhibited the controller nor set CURVEC1−X−RESET = HIGH, it is
not possible to change to another profile (error number 7;
ILLEGAL_SYSTEM_ACCESS).

2. Select the new profile (e.g. with FEVAN)

3. Wait 20 ms for data transfer

4. Initialisation starts with CURVEC1−CAM−SEL−BUSY = HIGH

5. Wait (approx. 20 ms) until CURVEC1−CAM−SEL−BUSY = LOW

6. Then CURVEC1−X−RESET = LOW.

)

Note!

Even if the controller is not inhibited, the profile can be changed with
CURVEC1−X−RESET = HIGH (e.g. via FEVAN).

During this procedure, the output CURVEC1−CAM−SEL−BUSY is HIGH.