Function library, Function blocks – Lenze EVS9332xK User Manual

Page 359

Advertising
background image

Function library

Function blocks

3.2.103

Stretching, compression, offset in Y direction (YSET1)

3−331

l

EDSVS9332K−EXT EN 4.0

3.2.103.1

Stretching/compression

YSET1−FACT

Stretching/compression

Direction reversal

+100 %

No

No

−100%

No

Yes, in Y position

>100 %

Stretching

No

<100 %

Compression

No

FIXED100%

No

No

Synchronised stretching/compression of drive motion

Synchronised stretching/compression of the drive motion is required for the following:

l

If master value and cam drive must run absolutely synchronously and

l

the factor must be changed during operation.

)

Note!

This function is only valid for the cam drive, not for the master drive!

This function should be used if more than 8 profiles are required to change the lift of
the cam drive.

The lift can be changed online via stretching and compression.

Function block interconnection

C1356/1

C1352/1

C1358/1

C1358/2

C1354/2

CDATA-X0

CDATA-SYNCH

CDATA-NOUT

C1357/1

C1353/1

C1359/1

C1359/2

C1355/2

YSET1-OFFS

YSET1-FACT

YSET1-OUT

YSET1-LIM

YSET1-IN

CTRL

YSET1-IN-SYNCH

YSET1-SYNCH

YSET1

YSET1-RESET

C1354/1

C1355/1

C1364/1 C1351

C1350

+

+

1

0

fb_yset1_1

Activate function

Activate function with C1313 = 1.

The changeover is carried out during zero crossing of the profile.

)

Note!

Stretching/compression in X direction can be carried out via the input
CDATA−XFACT.

3.2.103.2

Offset

Use input YSET1−OFFS to shift the Y position by a constant value.