12 configuring the digital inputs and outputs, Commissioning – Lenze ECSCMxxx User Manual

Page 140

Advertising
background image

Commissioning

Configuring the digital inputs and outputs

6

l

140

EDBCSXM064 EN 11.0

6.12

Configuring the digital inputs and outputs

The signal assignment for the digital inputs can be set via code C4011. This code is included
in the GDC parameter menu under Short setup

W Digital inputs/outputs.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C4011

0

Assignment (mapping) of the
digital inputs
(from Motion V3.0)

l

QSP: Quick stop

l

SYNC: Synchronisation signal

l

Ref: Reference switch

l

Lp: Limit switch in pos.
direction

l

Ln: Limit switch in neg.
direction

^ 140

0

DI1: QSP
DI2: Ref
DI3: Lp
DI4: Ln

Setting for control via the
MotionBus (CAN interface X4).

l

Setting C4010 = 0

^ 141

1

DI1: SYNC
DI2: Ref
DI3: Lp
DI4: Ln

Setting for control via EtherCAT
(AIF interface X1)

l

X6/DI1 serves as an input for
the synchronisation signal for
EtherCAT.

l

Setting C4010 = 2