Commissioning steps (overview)

Basic settings with GDC

6

l

95

EDBCSXM064 EN 11.0

Detailed

information

Brief description

Settings

9.

Set feedback system.

l

Set Lenze motors with resolvers (standard) in the GDC
parameter menu under Short setup

W Feedback system.

l

Set other resolvers and encoders in the GDC parameter
menu under Motor/feedback systems

W Feedback

system.

^ 109

10. Select the control interface.

l

Set C4010 in the GDC parameter menu under Short
setup

W Control/operating mode.

^ 130

11. Set toggle bit monitoring.

Set the following codes in the GDC parameter menu under
Motion

W Toggle bit monitoring:

l

C3160 (toggle bit error handling)

l

C3161 (toggle bit error counter limit)

^ 136

12. A Set signal assignment of

the digital inputs.

Set C4011 in the GDC parameter menu under Short setup

W

Digital inputs/outputs:

l

0: Control via the CAN interface X4 (MotionBus)

l

1: Control via the AIF interface X1 (for EtherCAT only)

^ 140

B Set the polarity of the

digital inputs and outputs.

l

Set IC0114/x (polarity X6/DI1 ... DI4) in the GDC
parameter menu under Terminals I/O

W Digital inputs.

l

Set C0118/1 (polarity X6/DO1) in the GDC parameter
menu under Terminals I/O

W Digital outputs.

^ 142

13. Enter machine parameters.

Set the following codes in the GDC parameter menu under
Motion

W Machine parameters:

l

C0011 (max. speed)

l

C0105 (deceleration time for quick stop (QSP))

l

C0596 (max. system speed)

l

C3030 (following error warning limit)

l

C3031 (following error limit FAIL−QSP)

l

C3032 (1st response when following error limit has been
reached)

l

C3033 (2nd response when following error limit has been
reached)

^ 138

14. Switch on the mains.

l

Green LED is blinking and red LED is off:
– Controller is ready for operation.

l

Green LED is off and red LED is blinking:
– An error has occurred. Eliminate the error before you

continue commissioning.

The basic settings are completed now.

Proceed as follows:

ƒ

Enable controller (

^ 183).

ƒ

Save parameters in the controller with C0003 = 1.

ƒ

Save parameter set with GDC in the parameter set file.

ƒ

Set homing (

^ 96).