Appendix, Code table – Lenze ECSCMxxx User Manual

Page 324

Advertising
background image

Appendix

Code table

12

l

324

EDBCSXM064 EN 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C3008 HomeMlim

10.0

Torque limit value for homing
mode C3010 = 16 or 17
(100.00 % = maximum torque
from C0057)

^ 153

^ 153

0.00

{0.01 %}

100.00

C3009 TimeHome

Mlim

100

Duration for detecting the
mechanical limit stop for homing
mode C3010 = 16 or 17

^ 153

^ 153

0

{1 ms}

65535

C3010 HomingMode

8

Homing mode

^ 143

^ 145

0

>_Rn_MP

Selection symbolism:

l

>: Movement in pos. direction

l

<: Movement in neg. direction

l

Lp: Limit switch in pos.
direction

l

Ln: Limit switch in neg.
direction

l

Rp: Pos. edge of the reference
switch

l

Rn: Neg. edge of the reference
switch

l

MP: Zero pulse/position of
the position encoder, once per
motor revolution

l

TP: Touch probe signal

l

Mlim: mechanical limit stop
(torque limit value)

Notes:

l

When using the homing
modes 0 ... 5, set C0540 = 2.

l

The mechanical limit stop is
defined as exceedance of the
torque limit C3008 for the
duration C3009.

l

When the last action listed is
executed, the home position
is set (e.g. zero pulse with
"MP"), even if the drive
continues traversing.

l

In all modes without limit
switch ("Lp" / "Ln") retracting
from the limit switch with
error handling set in C3175 is
not possible.

1

<_Rn_MP

2

>_Lp_<_Rn_MP

3

<_Ln_>_Rn_MP

4

>_Rp_<_Rn_MP

5

<_Rp_>_Rn_MP

6

>_Rn_>_TP

7

<_Rn_<_TP

8

>_TP

9

<_TP

10

>_Lp_<_TP

11

<_Ln_>_TP

12

>_Lp_<_MP

13

<_Ln_>_MP

14

>_MP

15

<_MP

16

>_MLim

17

<_MLim

99

Set reference

C3011 Home offset

0

Offset between home position
and standstill position

^ 155

−2140000000

{1 inc}

2140000000

C3012 Measure offs.

0

Offset for shifting the zero
position with regard to the
standstill position

^ 155

−2147483647

{1 inc}

2147483647

C3020 ManJog

25.0

Manual jog speed in % of C0011
(maximum speed)

^ 165

−0.00

{0.01 %}

100.00

C3021 ACC−CTRL

enable

1.0

Acceleration time:
Within this time, the manual jog
speed (C3020) is reached.

^ 165

0.000

{1 s}

999.000

Advertising