Z80 Instruction Set

UM008007-0715

162

Z80 CPU
User Manual

r identifies registers B, C, D, E, H, L, or A specified in the assembled object code field, as
follows:

Description

The contents of the s operand are compared with the contents of the Accumulator. If there
is a true compare, the Z flag is set. The execution of this instruction does not affect the
contents of the Accumulator.

Condition Bits Affected

S is set if result is negative; otherwise, it is reset.

Z is set if result is 0; otherwise, it is reset.

H is set if borrow from bit 4; otherwise, it is reset.

P/V is set if overflow; otherwise, it is reset.

N is set.

C is set if borrow; otherwise, it is reset.

Example

If the Accumulator contains

63h

, the HL register pair contains

6000h

, and memory loca-

tion

6000h

contains

60h

, the instruction CP (HL) results in the PN flag in the F Register

resetting.

Register

r

B

000

C

001

D

010

E

011

H

100

L

101

A

111

Instruction

M Cycles

T States

4 MHz E.T.

CP r

1

4

1.00

CP n

2

7(4, 3)

1.75

CP (HL)

2

7 (4, 3)

1.75

CP (IX+d)

5

19 (4, 4, 3, 5, 3)

4.75

CP (lY+d)

5

19 (4, 4, 3, 5, 3)

4.75