Z80 Instruction Description
Z80 CPU
User Manual
297
INIR
Operation
(HL) ← (C), B ← B – 1, HL ← HL +1
Op Code
INIR
Operands
None.
Description
The contents of Register C are placed on the bottom half (A0 through A7) of the address
bus to select the I/O device at one of 256 possible ports. Register B is used as a byte coun-
ter, and its contents are placed on the top half (A8 through A15) of the address bus at this
time. Then one byte from the selected port is placed on the data bus and written to the
CPU. The contents of the HL register pair are placed on the address bus and the input byte
is written to the corresponding location of memory. Then register pair HL is incremented,
the byte counter is decremented. If decrementing causes B to go to 0, the instruction is ter-
minated. If B is not 0, the Program Counter is decremented by two and the instruction
repeated. Interrupts are recognized and two refresh cycles execute after each data transfer.
If B is set to 0 prior to instruction execution, 256 bytes of data are input.
If B ≠ 0:
If B = 0:
M Cycles
T States
4 MHz E.T.
5
21 (4, 5, 3, 4, 5)
5.25
M Cycles
T States
4
MHz E.T.
4
16 (4, 5, 3, 4)
4.00
1
1
0
0
1
1
1
1
ED
1
0
1
1
0
0
1
0
B2
Note: