BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
101
PONSetup:CURRent
This command sets the initial current limit at the power on. The maximum allowable current
is controlled by the voltage range and voltage mode.
Command Syntax
[SOURce:]PONSetup:CURRent <NRf+>
Parameters
range set by the LIMit:CURRent, voltage mode and voltage range
Examples PONS:CURR
22
Query Syntax
PONS:CURR?
Returned Parameters
<NR2>
PONSetup:FREQuency
This command sets the initial frequency of the power source at the power on.
Command Syntax
[SOURce:]PONSetup:FREQuncy <NRf+>
Parameters
set by the LIMit:FREQuency
Examples PONS:FREQ
50
Query Syntax
PONS:FREQ?
Returned Parameters
<NR2>
PONSetup:NOUTput
This command sets the configuration of the power source to one phase or three phase if this
option is enabled. The LAST setting causes the unit to power up in the mode it was left.
Command Syntax
[SOURce:]PONSetup:NOUTput <selection>
Parameters ONEPhase|THReephase|LAST
Examples PONS:NOUT
LAST
Query Syntax
PONS:NOUT?
Returned Parameters
<CRD>
PONSetup:OLOad[:MODE]
This command determines how the power source will react to an over current condition. In
const current mode, the output voltage is reduced to a value that maintains a constant laod
current. In constant voltage mode, the output faults to an initial value if the over current
condition is maintained beyond the protection delay period.
Command Syntax
[SOURce:]PONSetup:OLOad[:MODE] <mode>
Parameters CCURrent|CVOLyage
Examples OLOad
CCUR
Query Syntax
PONS:OLO?
Returned Parameters
<CRD>
Related Commands
CURR:PROT:STAT