AMETEK BPS Series Programming Manual User Manual
Page 55

BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
55
4.5
Array Measurement Subsystem
[3Pi Controller Only]
This command subsystem lets you retrieve arrays containing measurement data. Only
current and voltage measurements are stored in an array. Two measurement commands
are available: MEASure and FETCh. A MEASure command triggers the acquisition of new
data before returning the readings from the array. A FETCh command returns previously
acquired data from the array.
Individual outputs of a three-phase source are specified by the setting of
INSTrument:NSELect.
Subsystem Syntax
MEASure | FETCh
:ARRay
:CURRent
[:DC]?
Returns
the
digitized instantaneous current
:HARMonic
[:AMPLitude]?
Returns
amplitudes of the first 50 harmonics
:PHASe?
Returns phase angles of the first 50 harmonics
:MODE
Selects waveform data transfer format
:VOLTage
[:DC]?
Returns the digitized instantaneous voltage
:HARMonic
[:AMPLitude]?
Returns
amplitudes of the first 50 harmonics
:PHASe?
Returns phase angles of the first 50 harmonics