Table 58. utility parameters oids – Comtech EF Data CDM-IP 300L User Manual
Page 277
CDM-IP 300L IP-Centric Satellite Modem
Rev. 1
CD/CDMIP300L.IOM
251
8.6.1.5 U
TILITY
P
ARAMETERS
Table 58. Utility Parameters OIDs
OID Description
cdmip300LUnitFramingMode
Unit framing mode. Can be set to:
0 Unframed
1 Framed
cdmip300LEdmacAddress
The EDMAC slave address will set the range of
addresses of distant-end units (modems and
transceivers) for which this unit will forward
messages. Only values that are integer multiples of
ten are permitted. Setting the EDMAC slave address
to 0 disables this function. Valid slave addresses
are between 0 and 9999.
cdmip300LUnitTestMode
Unit test mode. Can be set to:
0 Normal
1
IF Loop Back
2 Digital
Loop
Back
3
IO Loop Back
4 Tx
CW
5
Tx Alternating Pattern
cdmip300LRecenterBuffer
Command to force the modem to re-center the
receive buffer. A value of 1 (yes) is used to issue
the operation.
cdmip300LForceRedundantSwitch Command to force the modem into STANDBY mode
if it is in a redundant pair. A value of 1 (yes) is used
to issue the operation.
cdmip300LUnitAlarmMask
Alarm mask conditions, in the form “abcde”, where:
a = mask Tx AIS alarm, b = mask Rx AGC alarm c =
mask buffer alarms, d = mask Rx AIS alarm e =
mask E
b
/N
0
alarm. Setting any of these bytes to 0
unmasks alarm, setting to 1 masks them. Valid
values are between 0 and 11111.
cdmip300LUnitConfigStore
Forces the unit to store the current modem
configuration in a configuration memory location
defined by values 0 to 9.
cdmip300LUnitConfigLoad
Forces the unit to retrieve the configuration memory
location defined by values 0 to 9 and to re-program
the unit with that stored configuration.