Table 62. odu system information oids, 9 odu o, 10 odu s – Comtech EF Data CDM-IP 300L User Manual
Page 282
CDM-IP 300L IP-Centric Satellite Modem
Rev. 1
CD/CDMIP300L.IOM
256
OID Description
cdmip300LRetrieveNext5Statistics
Unit returns the oldest 5 Stored Statistics which
have not yet been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body=
AA.ABB.BC.CD.Dddmmyyhhmmss,
AA.A = Minimum E
b
/N
o
during sample period.
BB.B = Average E
b
/N
o
during sample period.
C.C = Max. Tx Power Level Increase during sample
period.
D.D = Average Tx Power Level Increase during
sample period.
ddmmyyhhmmss = date/time stamp.
If there are less than 5 statistics to be retrieved, the
remaining positions are padded with zeros.
8.6.1.9 ODU O
BJECTS
The “oduSelect” determines with which transceiver to communicate. It can be set to:
1 Odu
1
2 Odu
2
8.6.1.10 ODU S
YSTEM
I
NFORMATION
Table 62. ODU System Information OIDs
OID Description
oduModelNumberSoftwareVer Read-only string describing the ODU model number and
software version.
oduUnitSerialNumber
Read-only string containing the ODU serial number.
oduDeviceTime
Time in hh:mm:ss format.
oduDeviceDate
Date in dd/mm/yy format.
oduCircuitID