Chapter 5: Monitor, Diagnostic, Maintenance
Monitor, Diagnostic, Maintenance

NGSME16T2H User Manual | 358

Maintenance

The section allows user to maintain the switch, such as Reset Factory Default,

Firmware upgrading, Configuration Save/Restore and Restart the device.

Restart Device

You can restart the switch on this page. After restart, the switch will boot normally.

Yes: Click to restart device.

No: Click to return to the Port State page without restarting.

Factory Defaults

You can reset the configuration of the switch on this page. Only the IP configuration

is retained.

The new configuration is available immediately, which means that no restart is

necessary.

Yes: Click to reset the configuration to Factory Defaults.

No: Click to return to the Port State page without resetting the configuration.

Note: Restoring factory default can also be performed by making a physical

loopback between port 1 and port 2 within the first minute from switch reboot. In the

first minute after boot, 'loopback' packets will be transmitted at port 1. If a 'loopback'

packet is received at port 2 the switch will do a restore to default.