Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 304

Advertising
background image

10 Appendix

10.2.2 Parameters

10-22

Pn50C

2

Input Signal Selection 3

0000 to FFFF

8888

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

/SPD-D Signal Mapping
(Refer to

5.6 Internal Set Speed Control

.)

Reference

Section

0

Active when CN1-15 input signal is ON (low level).

5.6.1

1

Active when CN1-16 input signal is ON (low level).

2

Active when CN1-17 input signal is ON (low level).

3

Active when CN1-18 input signal is ON (low level).

4

Active when CN1-25 input signal is ON (low level).

5

Active when CN1-26 input signal is ON (low level).

6

Active when CN1-12 input signal is ON (low level).

7

Reserved (Do not change.)

8

Not active (fixed).

9

Active when CN1-15 input signal is OFF (high level).

A

Active when CN1-16 input signal is OFF (high level).

B

Active when CN1-17 input signal is OFF (high level).

C

Active when CN1-18 input signal is OFF (high level).

D

Active when CN1-25 input signal is OFF (high level).

E

Active when CN1-26 input signal is OFF (high level).

F

Active when CN1-12 input signal is OFF (high level).

/SPD-A Signal Mapping
(Refer to

5.6 Internal Set Speed Control

.)

Reference

Section

0 to F

Same as /SPD-D Signal Mapping.

5.6.1

/SPD-B Signal Mapping
(Refer to

5.6 Internal Set Speed Control

.)

Reference

Section

0 to F

Same as /SPD-D Signal Mapping.

5.6.1

/C-SEL Signal Mapping (Control method change when ON (L-level))

Reference

Section

0 to F

Same as /SPD-D Signal Mapping.

5.7.1

4th 3rd 2nd 1st

digit digit digit digit

n.