2) changing output signal allocations, Analog – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 54

Advertising
background image

3.3 I/O Signal Allocations

3-19

3

Wi

ring and

C

onne

ctio

n

(2) Changing Output Signal Allocations

Output signals are allocated as shown in the following table.

Refer to the

Interpreting the Output Signal Allocation Tables

and change the allocations accordingly.

<Interpreting the Output Signal Allocation Tables>

• The signals not detected are considered as

"

Invalid.

"

For example, Positioning Com-

pletion (/COIN) signal in speed control is

"

Invalid.

"

• Inverting the polarity of the brake signal (/BK), i.e. positive logic, will prevent the hold-

ing brake from working in case of its signal line disconnection.
If this setting is absolutely necessary, check the operation and confirm that there are
no safety problems.

• When two or more signals are allocated to the same output circuit, a signal is output

with OR logic circuit.

Output Signal Names

and Parameters

Output Signal

CN1 Pin Numbers

Invalid

(not use)

7

9

10

Positioning Completion

Pn50E.0

/COIN

1

2

3

0

Speed Coincidence

Detection

Pn50E.1

/V-CMP

1

2

3

0

Rotation Detection

Pn50E.2

/TGON

1

2

3

0

Servo Ready

Pn50E.3

/S-RDY

1

2

3

0

Torque Limit Detection

Pn50F.0

/CLT

1

2

3

0

Speed Limit Detection

Pn50F.1

/VLT

1

2

3

0

Brake

Pn50F.2

/BK

1

2

3

0

Warning

Pn50F.3

/WARN

1

2

3

0

Near

Pn510.0

/NEAR

1

2

3

0

Reference Pulse Input

Multiplication Switching

Output

Pn510.2

/PSELA

1

2

3

0

Pn512.0=1

Polarity inversion of CN1-7

0

(Not invert at fac-

tory setting)

Pn512.1=1

Polarity inversion of CN1-9

Pn512.2=1

Polarity inversion of CN1-10

Output Signal

CN1 Pin Numbers

Invalid

not use

7

9

10

Positioning Completion

Pn50E.0

/COIN

1

2

3

0

The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the
selected set values.
Values in cells in bold lines are the factory settings.

Output Signal Names

and Parameters

Analog