Marantz PDxx01 User Manual

Page 13

Advertising
background image

PDxx01

RS-232C Control Specification Page: 13 / 49

Document Version [1.0]

Company Restricted

5-13.

COLOR TEMP SELECT

Function
The external control equipment changes the COLOR TEMP of the plasma monitor.

Transmission Data

DFH 80H 60H 00H 01H DATA00 CKS

DATA00: 00H:

low

01H:

middle

02H:

high

03H: middle low

ACK

7FH 60H 80H 00H 01H DATA00 CKS

DATA00: 00H:

low

01H:

middle

02H:

high

03H: middle low

5-14.

RED Gain Data

Function
The external control equipment changes the RED Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: RED Gain Flag

01H

DATA02: RED Gain 1(Bias)

D8H : -40

:

FFH : -01

00H : 0

01H : +01

:

1EH : +30

DATA03: RED Gain 2(Drive)

D8H : -40

:

FFH : -01

00H : 0

01H : +01

:

1EH : +30

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: RED Gain Flag

01H

Advertising