RS-232C Control Specification

Page: 48 / 49

Document Version [1.0]

Company Restricted

5-76.

REMOTE CODE SETTING

Function

Remotecontroler codes are set.

Transmission Data
DFH 80H 60H 2BH 01H DATA00 CKS

DATA00

00H:

ALL

01H:

CODE1

02H:

CODE2

03H:

CODE3

04H:

CODE4

ACK
7FH 60H 80H 2BH 01H DATA00 CKS

DATA00

00H:

ALL

01H:

CODE1

02H:

CODE2

03H:

CODE3

04H:

CODE4

5-77.

VOLUME Gain Data REQUEST

Function
The external control equipment inquires the volume gain for Plasma diaplay.

Transmission Data
1FH 80H 60H 0EH 00H CKS

ACK
DFH 60H 80H 0EH 01H DATA00 CKS

DATA00: VOLUME Gain

: 00H~2AH

(00H: 0、0FH:15、10H:16、1FH、31・・・2AH:42)

: FFH: MUTE

5-78.

UNDER SCAN SETTING

Function

Under scan are set up.

Transmission Data
DFH 80H 60H 22H 01H DATA00 CKS

DATA00:

00H

OFF

01H

ON

ACK
7FH 60H 80H 22H 01H DATA00 CKS

DATA00:

00H

OFF

01H

ON