PDxx01

RS-232C Control Specification

Page: 35 / 49

Document Version [1.0]

Company Restricted

DATA06: RESET

00H: OFF
01H: ON

ACK

7FH 60H 80H 0DH 00H CKS

5-49.

GAMMA GAIN Data

Function
External control apparatus changes Gamma of a plasma monitor.

Transmission Data

DFH 80H 60H 13H 02H DATA00 DATA01 CKS

DATA00: GAMMA FLAG

01H: Gamma change

DATA01: GAMMA

00H:

1(GAMMA2.1)

01H: 2(GAMMA2.2)

02H: 3(GAMMA2.3)

03H: 4(GAMMA2.4)

ACK

7FH 60H 80H 13H 01H DATA00 CKS

DATA00: GAMMA FLAG

01H: Gamma change

5-50.

Running Sense

Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.

Transmission Data

1FH 80H 60H 88H 00H CKS

ACK

7FH 60H 80H 88H 01H DATA CKS

DATA: Bit0: Connect Condition

0: No connection

1: Connected

Bit1 0: Fixed

1:-

Bit2: Power Status

0: POWER ON

1: POWER OFF (STANBY)

Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed