5-66.

PICTURE MEMORY Set

Function
The external control equipment ser and reset the Picture Memory function of a plasma monitor.

Transmission Data

DFH 80H 60H 25H 02H DATA00 DATA01 CKS

DATA00:

01H:

SET

02H:

RESET

DATA01: MEMORY select

00H: OFF

01H:

MEMORY1

02H:

MEMORY2

03H:

MEMORY3

04H:

MEMORY4

05H:

MEMORY5

06H:

MEMORY6

ACK

The plasma monitor returns the following ACK when the input is switched.

7FH 60H 80H 25H 01H CKS

DATA00:

01H:

SET

02H:

RESET




5-67.

PICTURE MEMORY NOTE WRITE Set

Function
External control apparatus writes to NOTE of PICTURE MEMORY o

f a plasma display.

Transmission Data

DFH 80H 60H 2DH 0FH DATA00 to DATA14 CKS

Even DATA00-DATA14 is set up as follows.

Setting value

00H-09H

: 0 - 9

80H

: - (Hyphen)

81H :

+

82H :

83H :

/

84H :

(

85H :

)

86H :

.

87H :

96H : Blank

10H-29H: A-Z of Alphabet

NOTE: When “PICTURE MEMORY” selects “OFF”, this command is no support.