Marantz PDxx01 User Manual

Page 36

Advertising
background image

PDxx01

RS-232C Control Specification

Page: 36 / 49

Document Version [1.0]

Company Restricted

5-51.

OSM ORBITER

Function
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.

Transmission Data

DFH 80H 60H 5FH 01H DATA00 CKS

DATA00

01H: ORBITER ON

02H: ORBITER OFF

ACK

7FH 60H 80H 5FH 01H DATA00 CKS

DATA00

01H: ORBITER ON

02H: ORBITER OFF

5-52.

Input Skip

Function
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.

Transmission Data

DFH 80H 60H 61H 01H DATA00 CKS

DATA00

01H:

ON

02H:

OFF

ACK

7FH 60H 80H 61H 01H DATA00 CKS

DATA00

01H:

ON

02H:

OFF

5-53.

SERIAL No. Request

Function
External control apparatus read

the serial number of the set recorded by EEPROM of a plasma display.



Transmission Data

1FH 80H 60H 15H 00H CKS

ACK

7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS

Even DATA00-DATA11 is set up as follows.

Setting value 00H-09H

: 0 - 9

96H

: Blank

10H-29H : A-Z of Alphabet

Advertising