Marantz PDxx01 User Manual

Page 16

Advertising
background image

PDxx01

RS-232C Control Specification Page: 16 / 49

Document Version [1.0]

Company Restricted

5-19.

TREBLE Gain Data

Function
The external control equipment changes the TREBLE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

DATA02: TREBLE Gain

F3H: -13

:

FFH:

-01

00H:

0

01H:

+01

:

0DH:

+13

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

5-20.

BALANCE Gain Data

Function
The external control equipment changes the BALANCE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BALANCE Gain Flag

02H

DATA02: BALANCE Gain

EAH: -22

:

FFH:

-01

00H:

0

01H:

+01

:

16H:

+22

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BALANCE Gain Flag

02H

Advertising