Marantz PDxx01 User Manual

Page 21

Advertising
background image

PDxx01

RS-232C Control Specification Page: 21 / 49

Document Version [1.0]

Company Restricted

5-31.

GRAY LEVEL Set

Function
The external control equipment sets the GRAY LEVEL of the plasma monitor.

Transmission Data

DFH 80H 60H C6H 01H DATA00 CKS

DATA00: GRAY LEVEL

00H: 0

:

0FH:

15

ACK

7FH 60H 80H C6H 01H DATA00 CKS

DATA00: GRAY LEVEL

00H: 0

:

0FH:

15

5-32.

CINEMA MODE Set

Function
The external control equipment switches on or off the CINEMA MODE of the plasma monitor.

Transmission Data

DFH 80H 60H C1H 01H DATA00 CKS

DATA00: CINEMA MODE Set

01H: ON

02H: OFF

ACK

7FH 60H 80H C1H 01H DATA00 CKS

DATA00: CINEMA MODE Set

01H: ON

02H: OFF

5-33.

LONG LIFE Set (PDP SAVER Set)

Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the plasma
monitor.

Transmission Data

DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS

DATA00: PLE

01H: 100% (AUTO)

02H: 75% (LOCK1)

03H: 50% (LOCK2)

04H: 25% (LOCK3)

DATA01: INVERSE/WHITE

01H: INVERSE

02H:

OFF

03H:

WHITE

DATA02: ORBITER (PICTURE SHIFT)

01H: AUTO1

02H:

OFF

03H:

AUTO2

ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness) or
WHITE:

3FH 60H 80H 6BH 00H CKS

Advertising