H. POSITION Gain Data

Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H.POSITION Gain Flag

02H

DATA02: H.POSITION Gain

80H: -128

:

FFH:

-01

00H:

0

01H:

+01

:

7FH:

+127

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H.POSITION Gain Flag

02H

5-24.

V. HEIGHT Gain Data

Function
The external control equipment changes the V-HEIGHT gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V-HEIGHT Gain Flag

07H

DATA02: V-HEIGHT Gain

00H: 0

:

40H:

+64

ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V-HEIGHT Gain Flag

07H

5-25.

H. WIDTH Gain Data

Function
The external control equipment changes the H-WIDTH gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H-WIDTH Gain Flag

08H

DATA02: H-WIDTH Gain

00H: 0

:

40H:

+64

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H-WIDTH Gain Flag

08H