Command – Marantz PDxx01 User Manual

Page 8

Advertising
background image

PDxx01

RS-232C Control Specification Page: 8 / 49

Document Version [1.0]

Company Restricted

5. Command

5-1.

Power ON

Function

The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4EH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched on.

3FH 60H 80H 4EH 00H CKS



5-2.

Power OFF

Function

The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4FH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched off.

3FH 60H 80H 4FH 00H CKS



5-3.

Input Switch Change

Function

The external control equipment switches the input of the plasma monitor.


Transmission Data

DFH 80H 60H 47H 01H DATA00 CKS

DATA00 : Input Select

01H : Video1

02H : Video2

05H : DVD/HD1

06H : DVD/HD2

07H : PC/RGB

0EH : DVD/HD3(HDMI)

1AH : DVD/HD4(HDMI)

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 47H 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

NOTE: Do not set the Power ON or Power OFF command continuously.

Advertising