Polycom SpectraLink 1725-36028-001 User Manual

Page 64

Advertising
background image

SpectraLink 8000 Telephony Gateway Administration Guide

The SpectraLink 8000 Telephony Gateway monitors the condition
of any SpectraLink 8000 SVP Server(s) on the system. In a single
SpectraLink 8000 SVP Server system, when the SVP Server goes
into Maintenance Lock, the Telephony Gateway will also lock and
set an alarm. No new calls will be allowed but calls in progress will
not be affected.

In multiple SVP Server systems, when one SVP Server goes into
Maintenance Lock, it sends a message to the Telephony
Gateway(s) which will stop using the locked SVP Server. It may
take up to 30 seconds for the message to reach the Telephony
Gateway. If all SVP Servers lock, then the Telephony Gateway will
also lock and set an alarm. No new calls will be allowed but calls in
progress will not be affected.

Checkout all phones

: If the TFTP server is on a PC, this command is

used to upgrade each handset without having to reset the Gateway.
This command forces all the handsets on the system to check in with
the Gateway. They will check their current software version vs. the
version stored on the TFTP server and download if needed. Any
handsets in a call will perform their checkout after the call is
complete.

Reset System

: If this option is selected, you will be prompted to reset

this SpectraLink 8000 Telephony Gateway.

Reset All Systems

: If this option is selected, you will be prompted to

reset all SpectraLink 8000 Telephony Gateways.
Press Esc to return to the

NetLink Wireless Telephone System

menu.

64

PN: 1725-36028-001_T.doc

Advertising