2... OMP-MODL System Base

Using the OMP-MODL

2-8

Terminal Strip Connections

The MLCPU-1 is provided with a terminal strip connector for connection of
power, input and output wiring (Figure 2... -4). The terminal strip connector
can be unplugged from the module allowing for quick disconnect and
reconnection of wiring. Connection details follow:

External Power

(Terminals 1 & 2)

An external power source may be used to power the OMP-MODL .
If an external power supply is connected to the OMP-MODL and its
supply voltage is greater than approximately 10.7 VDC, the OMP-
MODL will operate from the external supply and the batteries will not
be used. In the event that the external power fails or drops below
10.7V, the OMP-MODL will automatically transfer to battery power
and continue operation.

The External Power Supply terminals will accept either AC or DC
input and polarity is not relevant.

E

XTERNAL

S

UPPLY

V

OLTAGE

R

ANGE

:

A field selectable dual input range feature allows the logger to
accomodate a very wide range of input voltage applied to the
External terminals. A jumper provided on the MLCPU-1
programs the input range for HI or LO range:

LO Range: (8 to 24 Vdc / 10 to 23 Vac) (factory default)

HI Range: (11 to 32 Vdc / 12 to 23 Vac)

STOP

RESET

ENABLE

POWER

SERIAL PORT

RELAY R2

RELAY R1

STATUS

FEEDBACK

EXTERNAL POWER

RELAY R1

RELAY R2

+5V

TTL ALARM OUTPUT

GND

1

2

3

4

5

6

7

8

9

ML004

Figure 2... -4: MLCPU-1 Terminal Strip Connections (end view)