FUNCTION:

The Constant icon represents a fixed User defined value. A typical application for the
Constant is as a threshold for use with the Comparator icon as shown below.

In the above net, when the temperature of the engine oil exceeds 130C, the relay output
will be energized.

INPUTS:

Data/Logic Signal: None.

Update Clock:

None

Enable:

None

OUTPUTS:

Output Signal:

Data type, fixed value of User definition.

ICON CONFIGURATION DIALOG BOX:

CONFIGURATION OPTIONS:

Icon Name: Specify the label for the icon. This name will show directly under the icon

within the Program Net.

Constant: Enter the constant value in this text box.

Output Name:

Specify the label for the Output. This name will show directly

under the Output terminal within the Program Net.