Warm-up – Omega Vehicle Security OMP-MODL User Manual

Page 247

Advertising
background image

11.. . A

PPENDIX

A: M

ASTER

I

CON

R

EFERENCE

U

SING THE

OMP-MODL

11-85

WARM-UP

F

UNCTION

I

CON

The Warm-up icon is is a special two Output terminal icon. It immediately outputs a logic
signal on one terminal upon receipt of an Update signal, then after a User programmed
delay, passes the Update signal to its second Output.
The typical application for the Warm-Up icon is to provide control of a power supply for
excitation of a sensor or transmitter and a short delay until the sensor/transmitter is read.
The following example Net illustrates that application. Upon receipt of the Update
command from the Sample Rate Clock, the Warm-up icon immediately cycles its Logic
Output terminalTrue which turns on the connected Relay Alarm icon to power up a
24VDC power supply for the 4-20mA loop excitation. The icon then waits for a User
defined period of time, then passes the Update command to the connected mA-Lo (4-
20ma) Input icon which then takes a sample. The next time the Net is executed, the
power supply is turned OFF.

INPUTS:

Update:

The icon immediately turns its Logic Output True when an Update
command is received. The Output staysTrue until the User provided time
expires.

Enable:

Processing of the icon is allowed when the Enable pin is

unconnected or when connected and Enable signal is TRUE.

OUTPUTS:

Output Signal 1:

Logic type. The Logic Output turnsTrue and staysTrue

immediately after receipt of an Update command.

Output Signal 2:

Update type. The Update command is passed through the icon

after a User defined delay (warm-up time).