HP StorageWorks 2.32 Edge Switch User Manual

Page 177

Advertising
background image

Edge Switch Element Manager user guide 177

Are you sure you want to send
firmware version?

This message requests confirmation to
send a firmware version from the
HAFM appliance’s firmware library to
the director. Firmware library can
store up to 8 firmware versions.

Click Yes to send the firmware version or
No to abort the operation.

Cannot change Port Type while
Management Style is FICON
without SANtegrity feature. Please
contact your sales representative.

Firmware is below the required level
and you attempted to change a port
type in the Configure Ports dialog box
while FICON management style, but
the optional SANtegrity Binding
feature is not installed.

Informational message. If the firmware is
below the required level, install SANtegrity
Binding before changing port types in the
Configure Ports dialog box while in
FICON management style.

Cannot create partition

<partition_number> while FICON

Management Server is enabled.

The user has moved slots into a

partition while FMS Server is enabled.

Disable FMS Server before moving slots

into a partition.

Cannot disable Switch Binding
while Enterprise Fabric Mode is
active and the switch is Online.

You attempted to disable Switch
Binding through the Switch Binding
Change State dialog box, but
Enterprise Fabric Mode is enabled.

You must either disable Enterprise Fabric
Mode using the Enterprise Fabric Mode
dialog box in the HAFM application or set
the switch offline before you can disable
Switch Binding.

Cannot disable Insistent Domain ID
while Fabric Binding is active.

You attempted to disable the Insistent
Domain ID parameter through the
Configure Switch Parameters dialog
box, but Fabric Binding is enabled.

Disable Fabric Binding through the Fabric
Binding dialog box before disabling these
parameters.

Cannot enable beaconing on a
failed FRU.

Occurs when selecting Enable
Beaconing option for a failed FRU.

Replace FRU and enable beaconing again
or enable beaconing on operating FRU.

Cannot enable beaconing while the
system light is on.

Occurs when choosing Enable
Beaconing option for a failed FRU.

Replace FRU and enable beaconing again
or enable beaconing on an operating
FRU.

Cannot enable beaconing while the
system error light is on.

Beaconing cannot be enabled while
the system error light is on.

Select Clear System Error Light from
Product menu to clear error light, then
enable beaconing.

Table 8

Element Manager messages (continued)

Message

Description

Action

Advertising