HP StorageWorks 2.32 Edge Switch User Manual

Page 18

Advertising
background image

Element Manager overview

18

Using the Element Manager, you can:

Back up and restore configuration data.

Clear the system error indicator.

Configure Fibre Channel operating parameters for the fabric, such as R_A_TOV, E_D_TOV,

switch priority, and interop mode. You can also configure Fibre Channel operating parameters

for the switch, such as preferred and insistent domain ID, rerouting delay, and domain RSCNs.

Configure individual ports with a port name describing the node attached to the port.

Configure keys for new features.

Configure interoperability mode for open switch fabrics.

Configure Preferred Paths for interswitch links (ISLs).

Configure link incident (LIN) alerts.

Configure a nickname to display instead of the world wide name (WWN) for the switch and

attached nodes.

Configure Port Binding and port speed.

Configure SNMP trap recipients and community names.

Configure Switch Binding if the optional SANtegrity Binding feature is installed.

Configure Open Trunking if the optional Open Trunking feature is installed.

Configure Open Systems Management Server features if the optional Open Systems

Management Server feature is installed.

Configure the switch name, location, description, and contact person.

Control individual Fibre Channel ports by blocking/unblocking operation, enabling LIN alerts

and Port Binding, and running internal and external loopback diagnostics.

Display field replaceable unit (FRU) properties such as the FRU name, physical position in the

switch (chassis slot number), active/failed state, part number, and serial number.

Display information for individual Fibre Channel ports, such as the port name, port number,

Fibre Channel address, operational state, type of port, and login data.

Display information on nodes attached to ports.

Display port performance and statistics.

Display vital product data for the switch, such as the system name, description, contact person,

location, status, model number, firmware and Engineering Change (EC) level, and

manufacturer.

Enable beaconing for ports and the switch unit.

Enable Alternate Control Prohibited (ACP) to restrict access to FICON switch connectivity

parameters.

Monitor the operational status of the switch and each of its hardware field-replaceable units.

Perform an initial program load (IPL).

Perform maintenance tasks for the switch, including maintaining firmware levels, administering

the Call Home Notification feature, accessing the switch logs, and collecting data to support

failure analysis.

Reset port operation.

Advertising
This manual is related to the following products: