HP StorageWorks 2.32 Edge Switch User Manual

Page 53

Advertising
background image

Edge Switch Element Manager user guide

53

07 Non-HP switch at other end of the ISL

—The cable is connected to a non-HP

switch, and interop mode is set to Open Fabric 1.0 mode.

08 ISL connection not allowed on this port

—The port type configuration

does not match the actual port use. (The port is configured as an F_Port, but attaches to a

switch or director.)

10 Port binding violation - Unauthorized WWN

—The WWN entered to

configure Port Binding for this port is not valid, or a nickname was used that is not

configured for the attached device in the Element Manager.

11 Unresponsive node connected to port

—Possible causes are:

• Hardware problem on switch or on a connected node where ELP frames are not

delivered, the response is not received, or a fabric login (FLOGI) cannot be received.

There may be problems in the switch SBAR.

• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out FLOGI within a reasonable time frame.

0x0C ESA Security Mismatch

—Processing of Exchange Security Attribute Frame

detected required security feature mismatch.

0x0D Fabric Binding Mismatch

—Fabric Binding is enabled and detected a switch

connection with an incompatible fabric membership list. Could also be the result of

problems delivering EFMD ILS.

0x0E Authorization Failure Reject

—The switch on the other side of the ISL

detected a security violation. This switch receives notification via a generic reject reason

code and sets its port to the invalid attachment state in sympathy.

0x0F Unauthorized Switch Binding WWN

—A Switch Binding error was detected on

either an E_Port or F_Port.

0x10 Authentication Failure.

ISL Authentication Check (CHAP) failed—If you wish

to allow the connection, update the authentication lists or disable authentication.

0x11 Fabric Mode Mismatch

—A connection was not allowed because:

• An HP M-Series switch or director attempted to connect to an HP switch or director

running in Open Fabric mode.

• An HP M-Series switch or director running in Open Fabric mode attempted to connect to

another vendor’s switch or director with an incorrect ELP revision level.

0x12 CNT WAN Extension Mode Mismatch

—The ELP maximum frame sizes were

incompatible because one product running in CNT WAN extension mode attempted to

connect to another product running in a normal mode.

Segmented E_Port messages:

Incompatible operating parameters, such as resource allocation

time-out values (R_A_TOV) or error-detect time-out values

(E_D_TOV) are inconsistent

—See

Configuring operating parameters

” on page 79

for more information.

Duplicate domain IDs

—See

Configuring operating parameters

” on page 79 for more

information.

Advertising