Information and error messages

190

Port speeds cannot be configured
at a higher rate than the director
speed.

This appears when you configure a
port to 2 Gb/sec and the director
speed is set to 1 Gb/sec.

Set the director speed to 2 Gb/sec in the
Configure Switch Parameter dialog box.

Port numbers must be in the range
of 0 to xxx.

When configuring Preferred Paths,
source ports and exit ports must be in
the range of ports for the switch being
configured.

In the Configure Preferred Paths dialog
box, change the numbers in the Source
Port and Exit Port fields to fall within the
port count of the switch on which you are
configuring paths.

Preferred Paths can not be enabled
until the Domain ID is set to
Insistent. Disable Preferred Paths,
then configure Switch Parameters.

If the switch’s domain ID has not been
set to Insistent, the user is not allowed
to activate the Preferred Path
configuration with the Enable
Preferred Paths check box selected.

Close the Configure Preferred Paths dialog
box and click Configure > Operating
Parameters > Switch Parameters. In the
Configure Switch Parameters dialog box,
click the Insistent check box.

R_A_TOV must be greater than
E_D_TOV.

R_A_TOV must be greater than
E_D_TOV.

Change one of the values so that
R_A_TOV is greater than E_D_TOV

Resource is unavailable.

The specified operation cannot be
performed because the product is
unavailable.

Verify that the Ethernet connection
between the HAFM appliance and the
director is up or available.

Resource is unavailable.

The specified operation cannot be
performed because the product is
unavailable.

Verify that the HAFM appliance-to-product
link is up. If the link is up, the HAFM
appliance may be busy. Try the operation
again later.

SANtegrity Feature not installed.
Please contact your sales
representative.

You selected Switch Binding from the
Configure menu, but the optional
SANtegrity Binding feature is not
installed.

Install the SANtegrity Binding key through
the Configure Feature Key dialog box
before using Switch Binding features.

Send firmware failed.

A firmware download operation
failed.

Retry the firmware download operation. If
the problem persists, contact the next level
of support.

SNMP trap address not defined.

If an SNMP community name is
defined, a corresponding SNMP trap
recipient address must also be
defined.

Enter a corresponding SNMP trap
recipient address.

Stop diagnostics failed. The test is
already running.

Diagnostics for the port was not
running and Stop was selected on the
Port Diagnostics dialog box.
Diagnostics quit for the port for some
reason, but the Stop button remains
enabled.

Verify port operation. Retry diagnostics for
the port and select Stop from the dialog
box. If problem persists, contact the next
level of support.

Table 8

Element Manager messages (continued)

Message

Description

Action