Industrial Data Systems IDS DT220 User Manual

Page 25

Advertising
background image

DT220 Users Manual version 1.a Configuration Parameters

21

1 - AND: <status>, <mode>, <polarity><weight><units><terminate>

Status:

OL (overload), ST (stable), US (unstable, in motion)

Mode:

GS (gross mode), NT (net mode)

Polarity:

+ (positive weight), - (negative weight)

Weight:

7 characters data, NOT zero blanked, with decimal point

Units:

lb, kg, t (ton), tn (tonne), g<sp> (gram), oz

Terminate:

lf, cr (line feed, carriage return)

2 - CONDEC: <stx><polarity><weight><units><mode>>status><terminate>

Polarity:

space (positive weight), - (negative weight)

Weight:

7 characters, zero blanked, with decimal point

Units:

L (lb), K (kg), T (ton), G (gram), O (oz)

Mode:

G (gross mode), N (net mode)

Status:

<space> (valid weight), M (motion), O (over wt), I(invalid)

Terminate:

lf, cr (line feed, carriage return)

3 - WEIGHTRONIX: <mode1><mode2><polarity><weight><space><units><term>

Mode1:

space (gross mode), 0 (zero if net mode)

Mode2:

G (gross mode), N (net mode)

Polarity:

+ (positive weight), - (negative weight)

Weight:

6 characters, NOT zero blanked, with decimal point

Units:

lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)

Terminate:

lf, cr (line feed, carriage return)

4 - OHAS:

<polarity><weight><space><units><2 spaces><mode><status><term>

Polarity:

space (positive weight), - (negative weight)

Weight:

7 digits, zero blanked, with decimal point

Units:

lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)

Mode:

G (gross mode), N (net mode)

Status:

<space> (valid weight), M (motion), O (over wt), I(invalid)

Terminate:

lf, cr (line feed, carriage return)

5 - Transmits the contents of DT220 registers.

Data entered into a text register can include other register data. Example of register 128

(Text1) emulating a Condec format without the polarity or status in Gross mode with lbs

units. Set TX Continuous Format setting to 128 and configure text register 128 to:

<A2><F81>GL<A10><A13> this = stx, 7 chars of gross wt, G, L, lf, cr

<Rreg no> = buffer register data, minimum size (zero blanked no spaces)

<Freg no> = buffer data, 7 character field, zero blanked, right justified.

<Iprint item> = Embed print item

<Axx> = Embed ACSII code