Industrial Data Systems IDS DT220 User Manual

Page 44

Advertising
background image

DT220 Users Manual version 1.a

Hardware & Wiring

40

Parallel Printer Port – 25 pin D connector J2

Pin # Signal Name

1

Strobe Output

2

TTL Output 1 (Printer Data 1)

3

TTL Output 2 (Printer Data 2)

4

TTL Output 3 (Printer Data 3)

5

TTL Output 4 (Printer Data 4)

6

TTL Output 5 (Printer Data 5)

7

TTL Output 6 (Printer Data 6)

8

TTL Output 7 (Printer Data 7)

9

TTL Output 8 (Printer Data 8)

10

11

Busy (input)

18-25 Ground (GND)

Load Cell Terminal Block

The load cell terminal block is located on the (optional 0113 PCB) plug-in the Analog

Input card inside the DT220. The Sense +/- inputs are jumped to Excitation +/- outputs

disabled from the factory. If remote sense is to be used remove or cut the jumpers located

on the bottom of the card/PCB.

Pin # Signal Name

1

+ Signal

2

- Signal

3

+ Excitation

4

+ Sense (Disabled default)

5

- Sense (Disabled default)

6

- Excitation

7

Analog ground