Industrial Data Systems IDS DT220 User Manual

Page 27

Advertising
background image

DT220 Users Manual version 1.a Configuration Parameters

23

Timers

There are 9 timers that can be used to trigger a function after a time interval. Each timer
has 2 parameters: Time (x0.1sec) and Function number. Use the

Cont.(↓↓↓↓) and

Review(↑↑↑↑) keys to position the edit block to a parameter value. Use the numeric keypad

to enter a new value. Press the

Enter key to complete the entry. Press the Clear Entry

key to exit timer data entry.

Keyboard

The keyboard event functions determine what actions take place when a key is pressed.

The Power on start function activates a function when power is applied to the indicator.
Use the

Cont.(↓↓↓↓) and Review(↑↑↑↑) keys to position the pointer to a parameter value. Press

the

Enter key. Use the numeric keypad to enter a new value. Press the Enter key to

complete the entry. Press the

Clear Entry key to exit timer data entry.

Scale Basic Fn Editor

Use the Scale Basic Function Editor to create or modify Scale Basic functions. The

display prompts: “Edit function number:”. Enter a function number to edit and press the

Enter key. The display shows the numeric codes in the scale basic function. Use the

Cont.(↓↓↓↓) and Review(↑↑↑↑) keys to position the edit block to a code position. Use the

numeric keypad to enter a new value. Press the

Enter key to complete the entry. Press

the

Clear Entry key to exit Scale Basic Fn Editor.


Scale Basic Debug Mode: (N)

The Debug mode is used to ‘debug’ scale basic functions. Enter ‘Y’ to activate debug

mode, enter a ‘N’ to disable debug mode. When debug mode is enabled Scale Basic

functions execute a ‘single step’ at a time

Display Update Rate (2)

Enter the time between display updates (in tenths of a second). An update rate of 1

causes a 0.1 second delay between display updates, a rate of 200 causes a 20 second delay

between updates. NOTE: motion detection is calculated using the weight values of the

display rate. If the update rate is 50, the motion calculation is based on weight readings

sampled at 5second intervals.

Enable TTL Inputs (Y)

Enter a Y to use TTL inputs 1-4 to activate scale basic functions 1 - 4. For example,

grounding TB3 pin 1 (TTL input 1) activates scale basic function 1.
Enter an ‘N’ to disable the TTL inputs.

Advertising