Hourmeter indicator troubleshooting, Electrical system, 8 hourmeter indicator troubleshooting – SkyTrak 6042 Service Manual User Manual

Page 446

Advertising
background image

Electrical System

9.76

Model 6042 Legacy

Origin 7/02

9.9.8

Hourmeter Indicator Troubleshooting

0000 00

P

With the park brake ON and

the engine running, check

wire 38 (ORG) for battery

voltage to instrument

cluster connector.

Hourmeter indicator

does not register

operating hours.

Not

OK

Check wire 2W (BLK) for

ground. Refer to Section

9.7.6, “Electrical Schematic

(Console/Stabilizer and

Engine Harnesses).”

Repair ground wire.

Not OK

Check alternator terminal “D+”

for battery voltage.

If

OK

If OK

Hourmeter

Indicator

MA7640

Before troubleshooting any
electrical circuit, ALWAYS
begin by checking the
following:

1. Fuses.

2. Battery for proper charge.

3. All connections relating to

circuit are clean and tight.

4. Check instrument cluster

bulbs for proper function.

Not OK

Replace instrument cluster.

Replace alternator.

Advertising