C00701 | la_nctrl: digital connection list, C00701/4, C00701/10 – Lenze E84DSxxx User Manual

Page 585: Which repres, Jogramp1, C00701/13, C00701/x, Ce in, C00701, 15 parameter reference

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

585

15

Parameter reference

15.2

Parameter list | C00701

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00701

Parameter | Name:

C00701 | LA_NCtrl: Digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Connection parameters for "Actuating drive speed" application: Binary inputs

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00701/1

0: Not connected

LA_NCtrl

: bCInh

(control input for setting controller inhibit)

C00701/2

16008: DigIn_CInh

LA_NCtrl

: bFailReset

(control input for error acknowledgement)

C00701/3

0: Not connected

LA_NCtrl

: bSetQuickstop

(control input for quick stop request)

C00701/4

16002: DigIn_bIn3

LA_NCtrl

: bSetDCBrake

(control input for DC-injection braking request)

C00701/5

0: Not connected

LA_NCtrl

: bRFG_Stop

(control input for stopping the speed ramp function

generator)

C00701/6

0: Not connected

LA_NCtrl

: bRFG_0

(control input for setting the speed ramp function

generator to 0)

C00701/7

0: Not connected

Reserved

C00701/8

16003: DigIn_bIn4

LA_NCtrl

: bSetSpeedCcw

(control input for change of direction of rotation)

C00701/9

16000: DigIn_bIn1

LA_NCtrl

: bJogSpeed1

(selection input for fixed setpoints)

C00701/10

16001: DigIn_bIn2

LA_NCtrl

: bJogSpeed2

(selection input for fixed setpoints)

C00701/11

0: Not connected

LA_NCtrl

: bJogSpeed4

(selection input for fixed setpoints)

C00701/12

0: Not connected

LA_NCtrl

: bJogSpeed8

(selection input for fixed setpoints)

C00701/13

0: Not connected

LA_NCtrl

: bJogRamp1

(selection input for additional acceleration/deceleration

times)

C00701/14

0: Not connected

LA_NCtrl

: bJogRamp2

(selection input for additional acceleration/deceleration

times)

C00701/15

0: Not connected

LA_NCtrl

: bJogRamp4

(selection input for additional acceleration/deceleration

times)

C00701/16

0: Not connected

LA_NCtrl

: bJogRamp8

(selection input for additional acceleration/deceleration

times)

C00701/17

0: Not connected

LA_NCtrl

: bMPOTInAct

(control input for deactivation of motor potentiometer)

C00701/18

0: Not connected

LA_NCtrl

: bMPOTUp

(control input for motor potentiometer ramp-up)

C00701/19

0: Not connected

LA_NCtrl

: bMPOTDown

(control input for motor potentiometer ramp-down)