15

Parameter reference

15.2

Parameter list | C02582

634

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Bit 1  [--]: nAct < nMin at CInh

Brake response in case of pulse inhibit

• "1" ≡ In the case of a pulse inhibit, the actual speed

value is monitored which must reach the "Close"

threshold value to cause the holding brake to be

applied.

Note:

• This function is only active if bit 3

(horizontal/winding technology) is set as well. The

function is used in order that, when the controller is

inhibited, the holding brake of a drive with horizontal

traverse path does not wear out during rotation.

• With vertical motion (bit 3 = 0), this function is not

active. Especially with hoists and activated pulse

inhibit of the controller, an immediate application of

the brake is essential for safety-related reasons!

Bit 2  [||]: Feedforward control inverted

Direction of feedforward control with vertical/hoist

technology:

• "0" ≡ Positive direction

• "1" ≡ Negative direction

Note:

Reversal (Ccw) is then considered.

Bit 3  [--]: Horizontal

Direction of movement of the axis

• "0" ≡ The axis performs vertical movements.

Gravitational acceleration causes movements.

• "1" ≡ The direction of the axis is horizontal or rotary.

The gravitational acceleration does not cause any

movement.

Bit 4  Reserved
Bit 5  Reserved
Bit 6  Sync ramp L_NSet_1

From version 11.00.00

Selection of the ramp time for the synchronisation

process to setpoint speed after the brake opening time

has elapsed

Revised behaviour from version 11.00.00:

• "1" ≡ The ramp time of the effective acceleration of

the ramp function generator (

L_NSet_1

) is used

(Lenze setting).

• "0" ≡ As before, the ramp time set in

C02610/1

is used.

Note:

The changeover can be dynamically both via the ramp

parameter and via bit 6.

Bit 7  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h