C00986 | slvc: cross current controller gain, C00987 | inverter motor brake: nadd, C00988 | inverter motor brake: pt1 filter time – Lenze E84DSxxx User Manual

Page 622: C00990 | flying restart fct.: activation, Tivated in, C00990, The flying r, C00987, C00988, Shou

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00986

622

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00986

C00987

C00988

C00990

Parameter | Name:

C00986 | SLVC: Cross current controller gain

Data type: INTEGER_16

Index: 23589

d

= 5C25

h

Gain of the cross current difference for the voltage model of the sensorless vector control (

SLVC

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

10.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00987 | Inverter motor brake: nAdd

Data type: INTEGER_16

Index: 23588

d

= 5C24

h

Speed lift which is connected in pulses to the brake rampe when the motor is braked.

Inverter motor brake

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

1000 80 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00988 | Inverter motor brake: PT1 filter time

Data type: INTEGER_16

Index: 23587

d

= 5C23

h

PT1 filter time for smoothing the speed lift which is added in pulses (

C00987

)

Inverter motor brake

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

100.0 0.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00990 | Flying restart fct.: Activation

Data type: UNSIGNED_8

Index: 23585

d

= 5C21

h

Switch on/activate flying restart circuit for non-feedback drive systems

Flying restart fct.

Selection list

(Lenze setting printed in bold)

0 Off
1 On

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1