Manual operation and setup

11.7

Datum setting with 3-D touch probe (Touch Probe Functions
software option 17)

11

310

TNC 128 | User's Manual HEIDENHAIN Conversational Programming | 5/2014

Measuring workpiece dimensions

Select the probing function: Press the

PROBING

POS soft key
Position the touch probe at a position near the first
touch point A

Select the probing direction by soft key

Start the probing procedure: Press the machine
START button

If you need the current datum later, write down
the value that appears in the Datum display

Datum: Enter "0"

Cancel the dialog: Press the

END key

Select the probing function again: Press the
PROBING POS soft key
Position the touch probe at a position near the
second touch point B

Select the probe direction with the soft keys:
Same axis but from the opposite direction

Start the probing procedure: Press the machine
START button

The value displayed as datum is the distance between the two
points on the coordinate axis.

To return to the datum that was active before the length
measurement:

Select the probing function: Press the

PROBING POS soft key

Probe the first touch point again

Set the datum to the value that you wrote down previously

Cancel the dialog: Press the

END key