HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual

Page 490

Advertising
background image

490

Touch Probe Cycles: Automatic Workpiece Inspection

1

7.1

1 MEA

S

URE COORDINA

TE

(Cy

c

le

427

, DIN/ISO: G427)

U

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR427.TXT
by default in the directory TNC:\.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.

U

Maximum limit of size

Q288: Maximum permissible

measured value. Input range 0 to 99999.9999

U

Minimum limit of size

Q289: Minimum permissible

measured value. Input range 0 to 99999.9999

U

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

U

Tool for monitoring

Q330: Definition of whether the

TNC is to monitor the tool (see "Tool monitoring" on
page 458). In
put range 0 to 32767.9; alternatively, tool
name with max. 16 characters:
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

Example: NC blocks

5 TCH PROBE 427 MEASURE COORDINATE

Q263=+35

;1ST POINT 1ST AXES

Q264=+45

;1ST POINT 2ND AXIS

Q261=+5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q272=3

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q260=+20

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG

Q288=5.1

;MAX. LIMIT

Q289=4.95 ;MIN. LIMIT

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

Advertising