Touch Probe Cycles: Automatic Workpiece Inspection
1
7.1
1 MEA
S
URE COORDINA
TE
(Cy
c
le
427
, DIN/ISO: G427)
U
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR427.TXT by default in the directory TNC:\.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.
U
Maximum limit of size
Q288: Maximum permissible
measured value. Input range 0 to 99999.9999
U
Minimum limit of size
Q289: Minimum permissible
measured value. Input range 0 to 99999.9999
U
PGM stop if tolerance error
Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
U
Tool for monitoring
Q330: Definition of whether the
TNC is to monitor the tool (see "Tool monitoring" on
page 458). Input range 0 to 32767.9; alternatively, tool
name with max. 16 characters:
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Example: NC blocks
5 TCH PROBE 427 MEASURE COORDINATE
Q263=+35
;1ST POINT 1ST AXES
Q264=+45
;1ST POINT 2ND AXIS
Q261=+5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q272=3
;MEASURING AXIS
Q267=-1
;TRAVERSE DIRECTION
Q260=+20
;CLEARANCE HEIGHT
Q281=1
;MEASURING LOG
Q288=5.1
;MAX. LIMIT
Q289=4.95 ;MIN. LIMIT
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL