2 hardware sensors – Intel STL2 User Manual

Page 32

Advertising
background image

Server Management

STL2 Server Board TPS

3-24

Monitors the event receiver

Controls secure mode, inlucluding video blanding, diskett write-protect monitoring, and
fornt panel lock/unlock initiation

Controls Wake-on-Lan via Magic Packet* support

3.2 Hardware Sensors

The following table lists the hardware sensors present on the STL2 server board.

Sensor Number

Sensor Type

Monitoring Device

01h

Temperature

ADM1024 Temperature

02h

Processor 1 internal

03h

Processor 2 internal

20h

Voltage

3.3V

21h

5V

22h

12V

23h

3.3V Standby

24h

Processor 1

25h

Processor 2

29h

1.5V

2Ah

2.5V

2Ch

SCSI-A 2.85V

2Dh

SCSI-B 2.85V

2Eh

SCSI-A Vref1

2Fh

SCSI-A Vref2

30h

SCSI-A Vref3

31h

SCSI-B Vref1

32h

SCSI-B Vref2

33h

SCSI-B Vref3

34h

Voltage (Discrete)

Performance Lags

40h

Fan

Baseboard Fan 1

41h

Baseboard Fan 2

42h

Baseboard Fan 3

60h

Processor

Processor 1 State

61h

Processor 2 State

70h

Power Distribution Board

Soft Power Control Failure (bit 5) Interlock Power

71h

Power Distribution Board Supply 1

Power supply Failure detected (bit 1)

72h

Power Distribution Board Supply 2

Power supply Failure detected (bit 1)

7Fh

Power Redundancy Lost

Redundancy Lost (bit 1)
Redundancy Regained (bit 0)

90h

Chassis Intrusion ID

Drive Bay Intrusion (bit 1)
LAN Leash Lost (bit 4)

91h

Security Violation

Secure Mode Violation Attempt (bit 0)

92h

Memory Error

ECC multiple bit error (bit 1)
ECC single bit error (bit 0)

93h

POST Memory Resize

Advertising