Server Management

STL2 Server Board TPS

3-26

Sensor Type

Sensor Type
Code

Sensor-Specific
Offset

Event

Remarks

Platform Security
Violation Attempt

06h

00h

Secured Mode Violation
Attempt

Power/sleep switch has been
activated while in Secure Mode

03h

Pre-boot Password Violation
(network boot Password)

Bad Password at PXE Boot

Processor

07h

00h

IERR

CPU IERR has occurred

01h

Thermal Trip

CPU Thermal Trip has occurred

02h

FRB1/BIST Failure

BIST Error has occurred

04h

FRB3/Processor
Startup/Initialization failure
(CPU didn’t start)

FRB3 Timeout has been detected

08h

Processor disabled

A processor has been Disabled

Memory

0Ch

00h

Correctable ECC

ECC 1-bit error occurred

01h

Uncorrectable ECC

ECC 2-bit error occurred

POST Memory Resize 0Eh

POST Memory Resize

Displays the total amount of memory
after memory failure

POST Error

0Fh

POST Error

POST Error occurred

Event Logging
Disabled

10h

00h

Correctable Memory Error
Logging Disabled

Displays ECC single bit error
monitoring disabled

01h

Event ‘Type’ Logging Disabled Monitoring of a certain event type

has been disabled

02h

Log Area Reset/Cleared

Displays the SEL area cleared.

03h

All Event Logging Disabled

Monitor for the entire BMC has been
disabled.

System Event

12h

00h

System Reconfigured

Setup change has occurred

01h

OEM System Boot Event (Hard
Reset)

Cold reset has been issued

Critical Interrupt

13h

00h

Front Panel NMI Dump Switch Dump switch has been activated

02h

I/O channel check NMI

ISA I/O Check has occurred.

04h

PCI SERR

PCI SERR occurred

05h

PCI PERR

PCI PERR occurred

Button

14h

00h

Power Button

Power switch has been activated

01h

Sleep Button

Sleep switch has been activated

02h

Reset Button

Reset switch has been activated

Module / Board

15h

CPU / Terminator Missing

CPU / Terminator is not mounted
correctly

System Boot Initiated 1Dh

03h

User requested PXE boot

PXE (Network) Booted

04h

Automatic boot to diagnostic

When the maintenance Utility
Booted

Boot Error

1Eh

00h

No bootable media

Boot Media does not exist.

02h

PXE Server not found

PXE Server is not found

00h

C: boot completed

ESM Pro installed OS has been
booted

02h

PXE boot completed

PXE boot for the express server is
finished (not supported)

03h

Diagnostic boot completed

Maintenance Utility has been booted
(not supported)