Intel STL2 User Manual

Page 61

Advertising
background image

STL2 Server Board TPS

Basic Input Output System (BIOS)

Revision 1.0

4-53

Code

Error Message

Failure Description

0230:

System RAM Failed at offset

System RAM error
Offset address

0231:

Shadow RAM Failed at offset

Shadow RAM Failed
Offset address

0232:

Extend RAM Failed at address line

Extended RAM failed
Offset address

0233:

Memory type mixing detected

Memory type mixing detected

0234:

Single – bit ECC error

Memory 1 bit error detected

0235:

Multiple- bit ECC error

Memory multiple-bit error detected

0250:

System battery is dead – Replace and run SETUP

NVRAM battery dead

0251:

System CMOS checksum bad – Default configuration
used

CMOS checksum error

0252:

Password checksum bad - Passwords cleared

0260:

System timer error

System timer error

0270:

Real time clock error

RTC error

0271:

Check date and time setting

RTC time setting error

02B0:

Diskette drive A error

02B2:

Incorrect Drive A type – run SETUP

Incorrect Drive A type

02D0:

System cache error – Cache disabled

CPU cache error

0B00:

Rebooted during BIOS boot at Post Code

0B1B:

PCI System Error on Bus/Device/Function

PCI system error in Bus/device/Function

0B1C:

PCI Parity Error in Bus/Device/Function

PCI system error in Bus/device/Function

0B50:

CPU#1 with error taken offline

Failed CPU#1 because an error was detected

0B51:

CPU#2 with error taken offline

Failed CPU#2 because an error was detected

0B5F:

Forced to use CPU with error

An error detected in the entire CPU

0B60:

DIMM group #1 has been disabled

Memory error, memory group #1 failed

0B61:

DIMM group #2 has been disabled

Memory error, memory group #2 failed

0B62:

DIMM group #3 has been disabled

Memory error, memory group #3 failed

0B63:

DIMM group #4 has been disabled

Memory error, memory group #4 failed

0B6F:

DIMM group with error is enabled

An error detected in all the memory

0B70:

The error occurred during temperature sensor reading

Error while detecting a temperature failure.

0B71:

System temperature out of the range

Temperature error detected.

0B74:

The error occurred during voltage sensor reading

Error while detecting voltage

0B75:

System voltage out of the range

System voltage error

0B7C:

The error occurred during redundant power module
confirmation

The error occurred while retrieving the power
information

0B80:

BMC Memory Test Failed

BMC device (chip) failed

0B81:

BMC Firmware Code Area CRC check failed

0B82:

BMC core Hardware failure

0B83:

BMC IBF or OBF check failed

Access to BMC address failed

0B90:

BMC Platform Information Area corrupted.

BMC device(chip) failed

0B91:

BMC update firmware corrupted.

0B92:

Internal Use Area of BMC FRU corrupted.

SROM storing chassis information failed

(Available for use except for FRU command
and EMP function)

Advertising