Repeat the operation on the other side.

Remove the M16 screw from the crankshaft. Screw the two bushing locking flanges onto the crankshaft using

4 M12 x 25 screws (1, fig. 89).

Apply LOCTITE 243 to the threads of the M12 x 25 screws (1, fig. 88).

Set the screws with a torque wrench, as shown in Section 3.

Measure the distance X indicated in fig. 86 between the conical bushing and the crankshaft bearing.

Screw in the M16 screw until there is a reduction in the distance X of between 0.7 mm and 0.8 mm (fig. 97).