Page 30
Apply the lug to the PTO shaft (1, fig. 105).
2.1.3 Increase and Reduction Classes
INCREASE TABLE FOR CRANKSHAFT AND CONNECTION ROD HALF-BEARINGS
Recovery classes
(mm)
P/N
Half-bearing
Upper
P/N
Half-bearing
Lower
Correction on the shaft pin
diameter
(mm)
0.25
F90931100
F90930100
Ø92.75 0/0.03 Ra 0.4 Rt 3.5
0.50
F90931200
F90930200
Ø92.50 0/0.032 Ra 0.4 Rt 3.5
INCREASE TABLE FOR PUMP CASING AND PLUNGER GUIDE
Recovery classes
(mm)
P/N
Plunger Guide
Adjustments on the Pump
Casing housing
(mm)
1.00
F74050243
Ø81 H6 +0.022/0 Ra 0.8 Rt 6