2.2.3 Dismantling the Piston-Supports-Seals Assembly

The piston assembly does not need periodic maintenance.

Operations are limited to a visual check of the draining of the cooling circuit. If there are anomalies/

oscillations in the outlet pressure gauge, or pulsations in the cooling circuit drainage hose (if elastic), then the

seal packing must be checked and, if necessary, replaced.

Separate the head and the spacer for liners from the pump casing as shown in 2.2.1 (from fig. 106 to fig. 113).

Remove the upper inspection cover (1, fig. 120) and the lower inspection cover (1, fig. 121) by unscrewing the

4 attachment screws. Slip off the O-rings and replace if necessary.

Remove the pumping elements with an open-ended wrench (1, fig. 122) and check their state of wear

(1, fig. 123) Replace them if necessary.