The LP seal must be inserted into the liner with the seal lip in the direction of travel of
the plunger (1, fig. 139 and 140), lightly lubricating the outside diameter with silicone
grease (OKS 1110 type). Replace the LP seal when it is worn.
Reassemble the seal support assembly (1, fig. 141 and 142), replacing the 1 and 2 components).